Details
Details
Indoor Unit | PEY-SP42JA |
Outdoor Unit | PUY-SP42YKA |
Cooling Capacity kW / BTU/h | 12.3 / 42000 |
Power supply (V/Ph/Hz) | 220-240V/1-Ph/50Hz |
Power Input kW | 4.59 |
ISEER W/W | 3.67 |
Airflow (Low-Medium-High) CFM | 1040-1225-1485 |
External Static Pressure Pa | 35-50-70-100-125 |
Noise Level (Low-Medium-High) dB(A) | 36-40-44 |
Indoor drain pipe outer diameter (mm) | 32 |
Indoor Dimensions WxDxH (mm) | 1400x732x250 |
Indoor Weight (kg) | 39 |
Control wiring copper (Sq.mm) | 3C x 1.5 |
Remote control cable size copper (Sq.mm) | 2C x 0.3 |
Airflow Outdoor CFM | 3071 |
Noise Level dB(A) | 56 |
Dimension Outdoor WxDxH (mm) | 1050x330x981 |
Outdoor Weight (kg) | 73 |
Maximum height difference (Meter) | 30 |
Maximum Piping Length (Meter) | 50 |
External Piping diameter (Liquid/Gas) mm-Inches | 9.52 / 15.88 (3/8 & 5/8) |
Chargeless piping length (Meter) | 10 |
Power cable copper (Sq.mm) | 5C x 1.5 |
Temperature operating range | 18-52℃ |
Outdoor breaker size (Sq.mm) | 16 |
- New Inverter Technology: New Inverter Technology has made it possible for units to operate at outdoor-air temperatures as high as 52℃ . Tropical Specification series units are perfect for cooling homes and offices in tropical regions.
- High De-Humidifying Capacity: Prevent the decrease of De-Humidifying capacity even when the room temperature approaches the preset temperature since outdoor units detect and control evaporating temperature.
- New R410A Lineup: From Low capacity 18,000 Btu to high capacity 48,000 Btu units available, the new models in the R410A Series have highest i SEER in industry compared with conventional non-inverter models. All models contribute to reducing energy consumption over a wide range of operating capacities
- Compact Indoor units: For all Models, unit height is unified to 250 mm. Compared to the previous model, height has been reduced, allowing installation in tight spaces such as ceiling cavities or drop-ceilings.
- Air Inlet: Units with bottom inlets make more noise than those with rear inlets. It is recommended that the rear inlet be selected when installing a unit in a room that has to be quiet, such as a bedroom.
- Wide Selection of Fan Speeds and External Static Pressure: Five-stage external static pressure conversions and three fan speed selections are available. Capable of being set to a maximum of 125 Pa, units are applicable to a wide range of building types.
- Full-dot Liquid-crystal display adopted: Easier to read thanks to use of a full-dot liquid-crystal display with back light, and easier to use owing to the adoption of a menu format that enabled the number of operating buttons to be reduced
- Multi language display: Control Panel operation in eight different languages.
- Auto-return: Prevents wasteful operation by automatically returning to preset temperature after specified operating time
- After adjusting the initial temperature on a hot day, it is easy to forget to return the temperature setting to original value. The Auto return function automatically resets the temperature back to original setting after a specified period of time, thereby preventing over cooling. The Auto return activation time can be set in 10-minute units in a range between 30 and 120 minutes.
- Operation Lock: Fixed Temperature setting promotes energy savings
- In addition to operation start/stop the operation mode temperature setting and air flow direction can be locked. Unwanted adjustment of temperature settings is prevented and an appropriate temperature is constantly maintained, leading to energy savings. This feature is also useful in preventing erroneous operation or tampering.
- Night Setback: Keep desired room temperature automatically
- This function monitors the room temperature and automatically activates the cooling mode when the temperature rises above the preset maximum temperature setting
- Weekly Timer: Set up to 8 patterns per day including temperature control
- The weekly Timer enable the setting of operation start and stop times and adjusting the temperature as standard features. Up to 8 patterns per day can be set , providing operation that matches the varying conditions of each period, such as number of customers in store
- Temperature range restriction: Temperature range restriction prevents over cooling
- Using a temperature that is 1℃ higher for cooling results in 10% reduction in power consumption.* Temperature range restriction limits the maximum and minimum temperature settings, contributing to prevention of over cooling.
- Advanced MA Remote Controller
- Dot Liquid-crystal display adopted: The adoption of dot liquid-crystal display (LCD) technology and a large display screen for the control panel optimize visibility. Operation and control status are easily read at a glance.
- Temperature range restriction: Air Conditioner operation restricted to within a specified operating range
- Set the upper and lower limits for temperature range during operation .Excessive cooling is prevented ,leading to increased energy saving.
- Weekly Timer: Introduced in response to market demand
- Temperature can be controlled on a weekly basis. Temperature settings and on/off control can be managed over a period of one week using Weekly Timer. Up to eight setting patterns per calendar day are possible.
- Auto-off Timer: Automatically turns off air conditioner
- Set the timer for air conditioner to turn off automatically. The timer can be set in range from 30 minutes up to 4 hours in 30-minute intervals. The "simple Timer" -starts/stops in units of 1 hour in a 72-hour period is set at time of shipment from the factory. It can be changed to the "Auto-off Timer" function using the remote controller.
- Operation Lock: Prevent operation settings from being changed
- Units can be set so that the operation mode can be changed. When "Operation lock" is activated, new temperature setting commands are not accepted , thereby ensuring that unit runs in the specified temperature range. This promotes energy savings and prevents erroneous /mischievous operation. Only the administrator can change settings when using the operation lock mode
Additional Info
Additional Info
Type | Inverter - Cooling only |
---|---|
Size | No |
Capacity | No |
Star Rating | No |
Tonnage | 3.5 |
Security Deposit | No |